Organic SEC (GPC) Column: Ultra-rapid Analysis

Scroll
HK-400
  • Newly developed styrene divinylbenzene copolymer monodisperse particles
  • Analysis time is reduced to about a sixth of conventional column's analysis time
  • Low column pressure even under high flow rate does not require its use with UHPLC device
  • The amount of solvent used is reduced to about a sixth
  • Fulfills USP L21 requirements
(High performance semi-micro columns)   [Housing material: SUS]
HK-400 series is recommended to be used with semi-micro type devices.Scroll
Product code Product name Plate number
(TPN/column)
Particle size (μm) Column size (mm)
I.D. x Length
F6025010 GPC HK-401   ≥ 9,000 3 4.6 x 150
F6025020 GPC HK-402 ≥ 12,000 3 4.6 x 150
F6025030 GPC HK-403   ≥ 9,000    3.5 4.6 x 150
F6026040 GPC HK-404L   ≥ 9,000    3.5 4.6 x 150
F6025050 GPC HK-405   ≥ 7,000 3 4.6 x 150
F6025060 GPC HK-406   ≥ 5,000    6.5 4.6 x 150
HK-404L is a mixed-gel column capable of analyzing samples over a wide range of molecular weight distribution.
Scroll
Product name Maximum pressure
(MPa/Column)
Flow rate (mL/min) Temperature (℃) Shipping solvent
Recommended Maximum Recommended Maximum
GPC HK-401 25 0.3 - 1.0 2.0 40 60 Tetrahydrofuran (THF)
GPC HK-402 20 0.3 - 1.0 1.5 40 60 Tetrahydrofuran (THF)
GPC HK-403 25 0.3 - 1.0 2.0 40 60 Tetrahydrofuran (THF)
GPC HK-404L 25 0.3 - 1.0 2.0 40 60 Tetrahydrofuran (THF)
GPC HK-405 25 0.3 - 1.0 2.0 40 60 Tetrahydrofuran (THF)
GPC HK-406 25 0.3 - 1.0 2.0 40 60 Tetrahydrofuran (THF)
(Guard filter for GPC HK series)Scroll
Product code Product name Contents
F6700200 GPC HK-G One holder and one filter
F6700100 GPC HK-G filter 3 filters
 
- Removes sample-origin insoluble components.
- Attach directly to the analytical column.
Usable solventsScroll
Solvents Product name
HK-401 HK-402 HK-403 HK-404L HK-405 HK-406
Chloroform
N,N-Dimethylformamide (DMF)
Toluene
Hexafluoroisopropanol (HFIP) ×
30 % HFIP/Chloroform
✓: Can be used ×: Cannot be used
Target molecular weight range and exclusion limitPlease use the following tables for reference purposes only when selecting columns. Scroll
Product name Measured with polystyrene (eluent: THF)
Target molecular weight range Exclusion limit
GPC HK-401 100 - 1,500 2,000
GPC HK-402 200 - 10,000 20,000
GPC HK-403 2,000 - 70,000 100,000
GPC HK-404L 100 - 1,000,000 1,000,000
GPC HK-405 10,000 - 2,500,000 4,000,000
GPC HK-406 30,000 - 8,000,000 10,000,000

Operation Manual / Certificate of Analysis

Operation Manuals and Certificate of Analysis / Inspection Certificate for the following products can be downloaded here.

Product Name Index

Related Products

Product Information (Related Information)

General Information on Packed Columns

introduction of column cleaning procedure and column test conditions etc.