Calibration Standards for Organic SEC (GPC)

When size exclusion chromatography (GPC or GFC) is performed, it is necessary to make a calibration curve. It is recommended that Shodex STANDARD be used to obtain the calibration curve. The molecular weight range of Shodex STANDARD are very narrow and molecular weights are measured accurately.
Please refer to Calibration Standards for Aqueous SEC (GFC).

 

 

Polystyrene (PS)
Scroll
SL-105
SM-105
SH-75
  • For organic solvent SEC (GPC)
  • Less branched polystyrene with anionic polymerization
  • Easily soluble in tetrahydrofuran (THF), chloroform, toluene, and o-dichlorobenzene (ODCB)
(Standard kit)Scroll
Product code Product name Contents Molecular weight (Mp) Range
F8601105 STANDARD SL-105 0.5 g × 10 kinds 580 - 18,000
F8602105 STANDARD SM-105 0.5 g × 10 kinds 1,180 - 3,210,000
F8603075 STANDARD SH-75 0.5 g ×   7 kinds 662,000 ~ 6,550,000
Expiration date:
Expiration date of an unopened standard is 4 years from the date stamped (YY.MM.DD) on the INSPECTION CERTIFICATE.
Scroll
STANDARD SL-105   STANDARD SM-105 STANDARD SH-75

Std.No.

Mp Mw/Mn

Std.No.

Mp Mw/Mn Std.No. Mp Mw/Mn
S-18
S-13
S-9.8
S-6.7
S-4.9
S-3.3
S-2.0
S-1.2
S-0.9
S-0.6
18,000
13,400
9,320
6,660
4,910
3,320
1,990
1,180
940
580
1.02
1.02
1.02
1.03
1.03
1.04
1.05
1.07
1.07
1.13
S-3210
S-1570
S-607
S-298
S-129
S-49
S-17
S-6.3
S-3.3
S-1.2
3,210,000
1,570,000
607,000
298,000
129,000
49,400
17,100
6,250
3,320
1,180
1.06
1.04
1.03
1.04
1.03
1.04
1.03
1.03
1.04
1.06
S-6550
S-3550
S-3020
S-2330
S-1860
S-885
S-662
6,550,000
3,550,000
3,020,000
2,330,000
1,860,000
885,000
662,000
1.07
1.05
1.03
1.03
1.04
1.05
1.04
Note:
Molecular weights (Mp, Mw/Mn) of a standard kit may vary depending on production lot.
(Structure formula of S series)  

 

 

Polymethylmethacrylate (PMMA)
Scroll
M-75
  • For organic solvent SEC (GPC)
  • Narrow molecular weight distribution range
  • Easily soluble in hexafluoroisopropanol (HFIP) and dimethylformamide (DMF)
(Standard kit)Scroll
Product code Product name Contents Molecular weight (Mp) Range
F8604075 STANDARD M-75 0.5 g × 7 kinds 3,310 - 1,020,000
Expiration date:
Expiration date of an unopened standard is 4 years from the date stamped (YY.MM.DD) on the INSPECTION CERTIFICATE.
Scroll
STANDARD M-75  

Std.No.

Mp Mw/Mn
M-1020
M-539
M-210
M-60
M-20
M-6.9
M-3.3
1,202,000
539,000
210,000
60,300
20,500
6,940
3,310
1.04
1.02
1.02
1.02
1.04
1.10
1.09
Note:
Molecular weights (Mp, Mw/Mn) of a standard kit may vary depending on production lot.

Operation Manual / Certificate of Analysis

Operation Manuals and Certificate of Analysis / Inspection Certificate for the following products can be downloaded here.