Organic SEC (GPC) Columns: Linear Calibration Type

Scroll
LF
  • Packed with unique multi-pore gels with a wide pore-size distribution
  • Highly linear calibration curve without inflection points
  • Achieves highly precise molecular weight distribution determination
  • Enables analysis over a broad range of molecular weights
  • Rapid analysis column (LF-604) and high performance analysis column (LF-404) are also available
  • LF-604 and LF-404 enables reduction of solvent use
  • Fulfills USP L21 requirements
(Standard columns)   [Housing material: SUS]Scroll
Product code Product name Plate number
(TPN/column)
Particle size (μm) Column size (mm)
I.D. x Length
F6021041 GPC LF-804 ≥ 17,000 6 8.0 x 300
F6709621 GPC LF-G (guard column) 6 4.6 x  10
Scroll
Product name Maximum pressure
(MPa/Column)
Flow rate (mL/min) Temperature (℃) Shipping solvent
Recommended Maximum Recommended Range
GPC LF-804 3.5 1.0 2.0 25 - 40 20 - 60 Tetrahydrofuran (THF)
GPC LF-G - - - 25 - 40 20 - 60 Tetrahydrofuran (THF)
(Rapid analysis download columns)   [Housing material: SUS]
LF-604 is recommended to be used with semi-micro type devices.Scroll
Product code Product name Plate number
(TPN/column)
Particle size (μm) Column size (mm)
I.D. x Length
F6021042 GPC LF-604 ≥ 9,000 6 6.0 x 150
F6709621 GPC LF-G (guard column) 6 4.6 x  10
Scroll
Product name Maximum pressure
(MPa/Column)
Flow rate (mL/min) Temperature (℃) Shipping solvent
Recommended Maximum Recommended Range
GPC LF-604 3.5 0.5 1.0 25 - 40 20 - 60 Tetrahydrofuran (THF)
GPC LF-G - - - 25 - 40 20 - 60 Tetrahydrofuran (THF)
(High performance semi-micro columns)   [Housing material: SUS]
LF-404 is recommended to be used with semi-micro type devices.Scroll
Product code Product name Plate number
(TPN/column)
Particle size (μm) Column size (mm)
I.D. x Length
F6021043 GPC LF-404 ≥ 14,000 6 4.6 x 250
F6709621 GPC LF-G (guard column) 6 4.6 x  10
Scroll
Product name Maximum pressure
(MPa/Column)
Flow rate (mL/min) Temperature (℃) Shipping solvent
Recommended Maximum Recommended Range
GPC LF-404 3.5 0.3 0.6 25 - 40 20 - 60 Tetrahydrofuran (THF)
GPC LF-G - - - 25 - 40 20 - 60 Tetrahydrofuran (THF)
Target molecular weight range and exclusion limitPlease use the following tables for reference purposes only when selecting columns. Scroll
Product name Measured with polystyrene (eluent: THF)
Target molecular weight range Exclusion limit
GPC LF-804 300 - 2,000,000 2,000,000
GPC LF-604 300 - 2,000,000 2,000,000
GPC LF-404 300 - 2,000,000 2,000,000

Operation Manual / Certificate of Analysis