CLNpak EV-2000 AC is used for GPC clean-up of pesticides residuals in food with acetone/cyclohexane eluent.
Sample:
- 1.Palmitic acid 10.Diazinon
- 2.Oleic acid 11.Malathion
- 3.Linolenic acid 12.Chlorpyrifos-methyl
- 4.Fluvalinate 13.Corn oil
- 5.Chinomethionate 14.Bis(2-ethylhexyl)phthalate
- 6.β-Carotene 15.Methoxychlor
- 7.Methoprene 16.Sulfur
- 8.Cyhalothrin 17.Perylene
- 9.Cyfluthrin

- Column
- :Shodex CLNpak EV-G AC (20 mm I.D. x 100 mm) + EV-2000 AC (20 mm I.D. x 300 mm)
- Eluent
- :Acetone/Cyclohexane=20/80
- Flow rate
- :5.0 mL/min
- Detector
- :UV (254 nm)
- Column temp.
- :25 ℃
Sample Name Index
- Bis(2-ethylhexyl)phthalate, Diethylhexyl phthalate
- Chinomethionate
- Chlorpyrifos-methyl
- Corn oil
- Cyfluthrin
- Cyhalothrin
- Diazinon
- Fluvalinate
- Linoleic acid
- Malathion
- Methoprene
- Methoxychlor
- Oleic acid
- Palmitic acid, Hexadecanoic acid
- Perylene
- Sulfur
- β-Carotene
Operation Manual / Certificate of Analysis
Operation Manuals and Certificate of Analysis / Inspection Certificate for the following products can be downloaded here.
Product Name Index
Applications
- Sample Preparation for Animal and Fishery Products According to Japanese MHLW Notification
- GPC Clean-up for Animal and Fishery Products According to Japanese MHLW Notification (1) (EV-2000 AC)
- GPC Clean-up for Animal and Fishery Products According to Japanese MHLW Notification (2) (EV200AC-12F)
- Example of GPC Clean-up for Animal and Fishery Products According to Japanese MHLW Notification (1) (Medium Fatty Tuna and Beef Fat) (EV-2000 AC)
- Example of GPC Clean-up for Animal and Fishery Products According to Japanese MHLW Notification (2) (Milk, Egg) (EV-2000 AC)
- Elution Profile for Pesticides (EV-2000 AC)
- Effects of Temperature on GPC Clean-up
- Effects of Eluent Composition on GPC Clean-up
- Elution Volume for Lipid and Fatty Acids (EV-2000 AC)
- Effects of Eluent Components
- Separation with Ethyl Acetate/Cyclohexane Eluent (EV-2000)
- Spinach Pigment Removal (EV-2000 AC)
- Spinach Pigment Removal - Removal Rate (EV-2000 AC)
- Effects of Sample Injection Volume
- Effects of Flow Rate (EV-2000 AC)
- Effects of Column Temperature
- Fractionation Standards (EV-2000 AC)