IgM from human serum was analyzed using aqueous solvent SEC (GFC) columns, OHpak SB-805 HQ and SB-806 HQ.
Sample : 50 μL
IgM, Immunoglobulin M from Human Serum
(Wako Pure Chemical Industries, Ltd.) 0.1 %
Columns : Shodex OHpak SB-806 HQ + SB-805 HQ (8.0 mm I.D. x 300 mm each) Eluent : 100 mM Sodium phosphate buffer (pH7.0) + 0.3 M NaCl Flow rate : 1.0 mL/min Detector : UV (254 nm) Column temp. : 30 °C
Sample Name Index
Operation Manual / Certificate of Analysis
Operation Manuals and Certificate of Analysis / Inspection Certificate for the following products can be downloaded here.
Product Name Index
Applications
- Sample Load (KW-803)
- Effects of Flow Rate (KW-802.5, KW-803)
- Standard Proteins (1) (KW-802.5)
- Standard Proteins (2) (KW-802.5 and KW-803)
- Standard Proteins (14) (KW-802.5)
- Standard Proteins (15) (KW-803)
- Standard Proteins (16) (KW-804)
- Standard Proteins (18) (KW-803)
- Standard Proteins (19) (KW-804)
- Standard Proteins (23) (GF-510 HQ)
- Standard Proteins (24) (KW402.5-4F)
- Standard Proteins (25) (KW403-4F)
- Standard Proteins (26) (KW404-4F)
- Standard Proteins (27) (KW405-4F)
- Recovery of Proteins (GF-310 HQ and GS-320 HQ)
- Recovery of Proteins (KW-802.5 and KW-803)
- Recovery of Proteins (KW-803)
- Proteins in Human Serum (3) (KW-803)
- Dimer and Trimer of BSA
- Crude Albumin (Chicken Egg) (1) (KW-803)
- Crude Lipoxidase
- Crude Catalase
- Crude Hexokinase
- Human Serum (1) (SB-802 HQ)
- Tryptic Digest of Human IgG
- Comparison of Chromatograms of Protein mixtures
- Comparison between KW402.5-4F and KW-802.5
- Recovery of Proteins (KW402.5-4F, KW403-4F)
- Human Control Serum
- Analysis of Whey in Yogurt (KW403 4F + KW402.5 4F)
- Lectin Protein
- Peptide Analysis (SEC)
- PEG-Chymotrypsin (KW-802.5)
- Poly-Lysine
- Avidin (2)
- α1 Acid Glycoprotein
- Analysis of Gelatin (SB-806M HQ)
- Comparison of SEC Separation of Standard Proteins
- Comparison of SEC Separation of Polyclonal Antibody
- Comparison of SEC Separation of Monoclonal Antibody
- Comparison of Separation of BSA Aggregates
- Monitoring Papain Digestion of Humanized Monoclonal IgG (LW-803)
- Analysis of Lipoproteins in Serum (KW-804)
- Comparison of SEC Separation of Standard Proteins between LW-403 4D and LW-803
- Durability Test by Number of Sample Injections (LW-403 4D)
- Comparison of Separation of Proteins with Conventional Device and Semi-micro Type Device (LW-403 4D)
- Comparison of IgG Separation with Conventional Device and Semi-micro Type Device (LW-403 4D)
- Particle Size Distribution Determination of Hepatitis B Surface Antigen Virus-like Particle (HBsAg VLP) (KW405-4F)
- Analysis of Hemocyanin (KW405-4F)
- SEC/MALS Analysis of Norovirus VLP (SB-805 HQ)
- Analysis of Thymosin α1 (KW-802.5)
- SEC/MALS Analysis of Exosome (SB-806 HQ)
Applications (Related Information)
- Calibration Curves for KW-800 Series (Pullulan)
- Calibration Curves for KW-800 Series (Proteins)
- Calibration Curves for KW-800 Series (PEG, PEO)
- Calibration Curves of KW400-4F (1) (Pullulan)
- Calibration Curves of KW400-4F (2) (Proteins)
- Calibration Curves of KW400-4F (3) (PEG, PEO)
- Calibration Curves for GF-HQ Series (Aqueous Eluent: Proteins)
- Calibration Curve for LW-803 (Proteins)
- Calibration Curve for LW-403 4D (Proteins)