Organic SEC (GPC) Columns: High Temperature / Ultra High Temperature Analysis

Print
HT-800 · Wide product lineup to support a broad range of molecular weight analysis
· Fulfills USP L21 requirements
UT-800 · Dedicated to SEC analysis at high/ultra high temperatures with a maximum usable temperature of 210 °C
· Suitable for the analysis of ultra high molecular weight polymer containing samples
· Fulfills USP L21 requirements

*The columns with 'M' at the end of column names are mixed-gel column capable of analyzing samples over a wide range of molecular weight distribution.

(Standard columns)
Shipping solvent: Toluene

Product codeProduct namePlate number
(TPN/column)
Particle size
(μm)
Size (mm)
I.D. x Length
F6208700
F6208710
F6208720
F6208730
F6208740
F6208770
F6709410
GPC HT-803
GPC HT-804
GPC HT-805
GPC HT-806
GPC HT-806M
GPC HT-807
GPC HT-G
≥ 7,000
  ≥ 7,000
  ≥ 7,000
  ≥ 7,000
≥ 7,000
  ≥ 4,000
(guard column)
13
13
13
13
13
18
13
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 50
F6208600
F6208610
F6208620
F6709400
GPC UT-802.5
GPC UT-806M
GPC UT-807
GPC UT-G
≥ 4,400
  ≥ 4,400
  ≥ 3,300
(guard column)
30
30
30
30
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 50
F6208390
F6700280
GPC AT-806MS
GPC AT-G
≥ 6,000
(guard column)
12
15
8.0 x 250
8.0 x 50
Product
name
Max. usable
pressure (MPa)
Recommended
flow rate (mL/min)
Max. usable
flow rate (mL/min)
Usable temp.
range (°C)
HT-803
HT-804
HT-805
HT-806
HT-806M
HT-807
HT-G

1.5
1.5
1.5
1.5
1.5
1.5
-

0.5 to 1.0
0.5 to 1.0
0.5 to 1.0
0.5 to 1.0
0.5 to 1.0
0.5 to 1.0
-
1.5
1.5
1.5
1.5
1.5
1.5
-
100 to 150
100 to 150
100 to 150
100 to 150
100 to 150
100 to 150
100 to 150
UT-802.5
UT-806M
UT-807
UT-G

1.0
1.0
1.0
-

0.3 to 1.0
0.3 to 1.0
0.3 to 1.0
-
1.5
1.5
1.5
-
100 to 210
100 to 210
100 to 210
100 to 210
AT-806MS
AT-G

2.0
-

0.5 to 1.0
-
1.5
-
*Ta to 150
*Ta to 150
*Ta: Ambient temperature

[Target molecular weight range and exclusion limit]
Please use the above table for reference purposes only when selecting columns.

Measured with polystyrene (eluent: *ODCB)
Product codeTarget molecular weight rangeExclusion limit
HT-803
HT-804
HT-805
HT-806
HT-806M
HT-807
1,000 - 50,000
7,000 - 300,000
50,000 - 2,000,000
150,000 - **(20,000,000)
1,000 - **(20,000,000)
300,000 - **(200,000,000)

70,000
400,000
4,000,000
**(20,000,000)
**(20,000,000)
**(200,000,000)

UT-802.5
UT-806M
UT-807
300 - 10,000
1,000 - **(20,000,000)
500,000 - **(200,000,000)

20,000
**(20,000,000)
**(200,000,000)

AT-806MS 1,000 - **(20,000,000)

**(20,000,000)

*ODCB: o-Dichlorobenzene
**( ) Estimated value

Contact us