• HOME
  • Product Search
  • Application Search
  • Distributors
  • Support

Organic SEC (GPC) Columns (General Analysis): Chloroform

Print
K-800 · Standard organic solvent SEC (GPC) column
· Supports a wide range of applications from low to high molecular weight compounds
· Fulfills USP L21 requirements

*Please refer to Replacement of In-Column Solvent
*Please refet to Solvent-peak Separation Columns for Organic SEC (GPC)
*The columns with ‘L’ or ‘M’ at the end of column names are mixed-gel column capable of analyzing samples over a wide range of molecular weight distribution.

(Standard columns)
[K-800 series] Shipping solvent: Chloroform

Product codeProduct namePlate number
(TPN/column)
Particle size
(μm)
Size (mm)
I.D. x Length
F6028110
F6028120
F6028125
F6028130
F6028194
F6028140
F6028195
F6028150
F6028196
F6028160
F6028190
F6028197
F6028198
F6700401
GPC K-801
GPC K-802
GPC K-802.5
GPC K-803
GPC K-803L
GPC K-804
GPC K-804L
GPC K-805
GPC K-805L
GPC K-806
GPC K-806M
GPC K-806L
GPC K-807L
GPC K-G 4A
≥ 18,000
  ≥ 18,000
  ≥ 18,000
  ≥ 18,000
  ≥ 18,000
  ≥ 18,000
  ≥ 18,000
  ≥ 11,000
≥ 11,000
  ≥ 11,000
  ≥ 13,000
≥ 11,000
  ≥ 6,000
(guard column)
6
6
6
6
6
7
7
10
10
10
10
10
18
8
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
8.0 x 300
4.6 x 10
For all products
Recommended flow rate: 0.5 to 1.0mL/min
Max. usable flow rate: 2.0mL/min
Max. usable pressure: 3.5 MPa
Max. usable temperature: 60°C

[Target molecular weight range and exclusion limit]
Please use the above table for reference purposes only when selecting columns.

Measured with polystyrene (eluent: Chroloform)
Product nameTarget molecular weight rangeExclusion limit
K-801
K-802
K-802.5
K-803
K-803L
K-804
K-804L
K-805
K-805L
K-806
K-806M
K-806L
K-807L
100 - 700
300 - 3,000
300 - 8,000
1,000 - 50,000
100 - 50,000
7,000 - 300,000
100 - 300,000
50,000 - 2,000,000
300 - 2,000,000
150,000 - *(20,000,000)
1,000 - *(20,000,000)
300 - *(20,000,000)
300 - *(200,000,000)

1,500
5,000
20,000
70,000
70,000
400,000
400,000
4,000,000
4,000,000
*(20,000,000)
*(20,000,000)
*(20,000,000)
*(200,000,000)

*( ) Estimated value

(Preparative columns) [Preparative columns are made to order. ]

Product codeProduct namePlate number
(TPN/column)
Particle size
(μm)
Size (mm)
I.D. x Length
Standard
column
F6102301
F6102312
F6102315
F6102303
F6102304
F6102305
F6102306
F6102309
F6700407
GPC K-2001
GPC K-2002
GPC K-2002.5
GPC K-2003
GPC K-2004
GPC K-2005
GPC K-2006
GPC K-2006M
GPC K-G 8B
≥ 18,000
≥ 18,000
  ≥ 18,000
≥ 18,000
≥ 14,000
  ≥ 10,000
≥ 10,000
≥ 10,000
(guard column)
6
6
6
6
7
10
10
10
15
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
8.0 x 50
K-801
K-802
K-802.5
K-803
K-804
K-805
K-806
K-806M
(guard column)

For all producs
Max. usable flow rate: 4.5 mL/min
Max. usable pressure: 2.0 MPa
Max. usable temperature: 60 °C

Contact us