Scroll
| UBNEW |
|
|---|
(Standard columns) [Housing material: SUS]Scroll
| Product code | Product name | Plate number (TPN/column) |
Particle size (μm) | Target Molecular Size (nm) | Column size (mm) I.D. x Length |
|---|---|---|---|---|---|
| F6429301 | UB-50NEW | ≥ 3,500 | 26 | < 50 | 8.0 x 300 |
| F6429302 | UB-100NEW | ≥ 3,500 | 27 | > 50 | 8.0 x 300 |
Scroll
| Product name | Maximum pressure (MPa/Column) |
Flow rate (mL/min) | Temperature range (℃) | pH range | Shipping solvent | |
|---|---|---|---|---|---|---|
| Recommended | Maximum | |||||
| UB-50, UB-100 | 0.5 | 0.5 - 1.0 | 2.0 | 4 - 60 | 2 - 14 | H2O |
Eluent conditions
- (1)Buffers and aqueous solutions of different salts can be used separately or together. Usable buffers include phosphate, acetate, citrate, and Tris. Usable aqueous salt solutions include sodium chloride, sodium sulfate, potassium sulfate, and ammonium sulfate. Their recommended concentration ranges are 0.05 to 0.3 M.
- (2)Up to 50 % (v/v) methanol, ethanol, isopropanol and acetonitrile are usable.
- (3)Aqueous solutions of urea, guanidine hydrochloride, and dithiothreitol (DTT) which are the protein denaturants can be used up to 8 M, 6 M, and 5 mM, respectively. However, their required concentration are usually high, which may damage the column during the solvent replacement. Thus, it is recommended to dedicate the column for these specific uses.
- (4)SDS surfactant can also be added up to 2% (w/v). However, since surfactants tend to remain on the column, solvent replacement after their use takes a longer time than replacement from general solvents. The replacement time can be shorten by using 30 to 50 % (v/v) methanol.
Operation Manual / Certificate of Analysis
Operation Manuals and Certificate of Analysis / Inspection Certificate for the following products can be downloaded here.
Product Name Index
Related Products
- Silica-based Aqueous SEC (GFC) Columns: PROTEIN KW-800
- High Performance Semi-micro Aqueous SEC (GFC) Columns: KW400
- Silica-based Aqueous SEC (GFC) Column for Analysis of Antibody Protein: PROTEIN LW
- Polymer-based Aqueous SEC (GFC) Columns: OHpak SB-800 HQ and SB-2000
- MALS Compatible Columns for Aqueous SEC (GFC): OHpak LB-800
Product Information (Related Information)
- Selection of Aqueous SEC (GFC) Columns
- Eluent Conditions for PROTEIN KW Series and LW Series
- Eluent Conditions for OHpak SB-800 HQ and LB-800
- Features of LB-800 Series (Comparison of Baseline Noise with Using MALS Detector)
- Separation Features of UB Series
- Durability Against Alkaline Solvents (UB Series)