MALS Compatible Columns for Aqueous SEC (GFC): OHpak LB-800

Scroll
LB-800
  • Polymer-based packed columns for aqueous SEC (GFC) analysis
  • Controlled column bleeding allows its use with light scattering detectors
  • The eluent can be replaced with DMF enabling the analysis of polar polymers
  • Fulfills USP-NF L38 and L39 requirements
  • LB-802.5 fulfills USP-NF L25 and L89 requirements
  • LB-803 fulfills USP-NF L37 requirements
(Standard columns)   [Housing material: SUS]Scroll
Product code Product name Plate number
(TPN/column)
Particle size (μm) Column size (mm)
I.D. x Length
F6429206 OHpak LB-802.5 ≥ 16,000   6 8.0 x 300
F6429201 OHpak LB-803 ≥ 16,000   6 8.0 x 300
F6429204 OHpak LB-804 ≥ 16,000 10 8.0 x 300
F6429203 OHpak LB-805 ≥ 12,000 13 8.0 x 300
F6429205 OHpak LB-806 ≥ 12,000 13 8.0 x 300
F6429202 OHpak LB-806M ≥ 12,000 13 8.0 x 300
F6709434 OHpak LB-G 6B (guard column) 13 6.0 x   50
LB-806M is a mixed-gel column capable of analyzing samples over a wide range of molecular weight distribution.
Scroll
Product name Maximum pressure
(MPa/Column)
Flow rate (mL/min) Temperature range
(℃)
pH range Shipping solvent
Recommended Maximum
OHpak LB-802.5,
OHpak LB-803
5.5 0.5 - 1.0 1.2 4 - 80 3 - 10 H2O
OHpak LB-804
- OHpak LB-806M
3.5 0.5 - 1.0 1.2 4 - 80 3 - 10 H2O
OHpak LB-G 6B - - - 4 - 80 3 - 10 H2O
Usable solventsScroll
Product name Maximum usable concentration (%)
Methanol Acetonitrile N,N-Dimethyformamide (DMF)
OHpak LB-802.5 - OHpak LB-806M, OHpak LB-G 6B 100 100 100
Target molecular weight range and exclusion limitPlease use the following tables for reference purposes only when selecting columns. Scroll
Product name Measured with pullulan (eluent: ultrapure water) Measured with **PEG/PEO (eluent: DMF)
Target molecular weight range Exclusion limit Target molecular weight range
OHpak LB-802.5 500 - 10,000          10,000 100 - 5,000
OHpak LB-803 1,000 - 100,000        100,000 500 - 50,000
OHpak LB-804 5,000 - 400,000     1,000,000 500 - 300,000
OHpak LB-805 100,000 - 1,000,000   *(4,000,000) 50,000 - 700,000
OHpak LB-806 100,000 - *(20,000,000) *(20,000,000) 70,000 - *(20,000,000)
OHpak LB-806M 500 - *(20,000,000) *(20,000,000) 200 - *(20,000,000)
*( ) Estimated value
** Polyethylene glycol/Polyethylene oxide

Operation Manual / Certificate of Analysis

Operation Manuals and Certificate of Analysis / Inspection Certificate for the following products can be downloaded here.

Product Name Index

Related Products

Product Information (Related Information)

General Information on Packed Columns

introduction of column cleaning procedure and column test conditions etc.