Shodex_HPLC_Columns_2023-2024
43/80

• Measured with *PEG/PEO (eluent: DMF) () —ll Aqueous SECGFCCoumns: H2OH2OH2OH2OPoymer-basedH2OH2OH2OGFC columns to be used with light scattering detector• Standard columnsUsable solventsTarget molecular weight range and exclusion limit• Measured with pullulan (eluent: ultrapure water)OHpak LB-802.5OHpak LB-803OHpak LB-804OHpak LB-805OHpak LB-806OHpak LB-806MOHpak LB-G 6BSB-802 HQSB-802.5 HQ, SB-803 HQSB-804 HQ - SB-806M HQSB-G 6BSB-807 HQ, SB-807GLB-802.5 - LB-806M, LB-G 6BSB-802 HQSB-802.5 HQSB-803 HQSB-804 HQSB-805 HQSB-806 HQSB-806M HQSB-807 HQLB-802.5LB-803LB-804LB-805LB-806LB-806MSB-802.5 HQSB-803 HQSB-804 HQSB-805 HQSB-806 HQSB-806M HQLB-802.5LB-803LB-804LB-805LB-806LB-806M8.0 x 3008.0 x 3008.0 x 3008.0 x 3008.0 x 3008.0 x 3006.0 x 50Product CodeProduct NameF6429206F6429201F6429204F6429203F6429205F6429202F6709434LB-806M is a mixed-gel column capable of analyzing samples over a wide range of molecular weight distribution. Product NameProduct NamePlease use the above table for reference purposes only when selecting columns.Plate Number(TP/column)≥ 16,000≥ 16,000≥ 16,000≥ 12,000≥ 12,000≥ 12,000(guard column)Maximum Usable Concentration (%)Methanol 0100 75 75 30100Target Molecular Weight Range200 - 1,000500 - 10,0001,000 - 100,0005,000 - 400,000100,000 - 1,000,000100,000 - * (20,000,000)500 - * (20,000,000)500,000 - * (500,000,000)500 - 10,0001,000 - 100,0005,000 - 400,000100,000 - 1,000,000100,000 - * (20,000,000)500 - * (20,000,000)Particle Size(µm)Pore Size 6 61013131313AcetonitrileN,N-Dimethylformamide (DMF) 0 0 75100 75100 75100 30 0100100Exclusion Limit1,00010,000100,0001,000,000* (4,000,000)* (20,000,000)* (20,000,000)* (500,000,000)10,000100,0001,000,000* (4,000,000)* (20,000,000)Please use the above table for reference purposes only when selecting columns. * (20,000,000)* ( ) Estimated value(Å)Column Size (mm)I.D. x Length 200 800 2,000 7,00015,00015,000Base Material: PolyhydroxymethacrylateUsable pH Range: pH3 - 10(Note)The maximum solvent tolerance of SB-2000 series, preparative columns of SB-800 HQ series, is 50 % methanol, acetonitrile, or DMF.(SB-2002 is not tolerant to organic solvents)Product NameTarget Molecular Weight RangeShipping Solvent100 - 2,000200 - 40,000500 - 300,00050,000 - 700,00070,000 - ** (20,000,000)200 - ** (20,000,000)100 - 5,000500 - 50,000500 - 300,00050,000 - 700,00070,000 - ** (20,000,000)200 - ** (20,000,000)*PEG : polyethylene glycol*PEO : polyethylene oxide** ( ) Estimated value41

元のページ  ../index.html#43

このブックを見る