| YS-50 | · Higher performance type of YK-421 · Applicable to analysis with or without suppressor method · Improved peak shape especially to divalent cations · Supports the analysis od alkylamines and transition metals |
| YK-421 | · Cation analysis with non-suppressor method · Simultaneous analysis of monovalent and divalent cations · Foe analysis of alkylamines |
| Y-521 | · Cation analysis with non-suppressor method · For amalysis of monovalent or divalent cations respectively |
| T-521 R-621 |
· T-521 and R-621 are aplicable to the analysis of transition metal and rare-earth metal ions respectively · High sensitivily achieved by using post-column fluorescence method |
| Product name | Plate number (TPN/column) |
Functional group |
Particle size (micron) |
Size(mm) ID x Length |
Shipping solvent |
|---|---|---|---|---|---|
| IC YS-50 IC YS-G |
> 5,500 Guard column |
Carboxyl Carboxyl |
5 5 |
4.6 x 125 4.6 x 10 |
4mM Methanesulfonic acid aq. 4mM Methanesulfonic acid aq. |
| IC YK-421 IC YK-G |
> 2,800 Guard column |
Carboxyl Carboxyl |
5 5 |
4.6 x 125 4.6 x 10 |
5mM Tartaric acid + 1mM Dipicolinic acid + 1.5g/L Boric acid aq. |
| IC Y-521 IC Y-G |
> 3,000
Guard column |
Sulfo Sulfo |
12 12 |
4.6 x 150 4.6 x 10 |
4mM HNO3 aq. 4mM HNO3 aq. |
| Product name |
Max. usable pressure (MPa) |
Max. usable flow rate (mL/min) |
Usable temp. range (deg-C) |
Shipping solvent |
|---|---|---|---|---|
| YS-50 IC YS-G |
10 - |
2.0 - |
20 to 60 20 to 60 |
4mM Methanesulfonic acid aq. 4mM Methanesulfonic acid aq. |
| YK-421 YK-G |
15 - |
1.5 - |
RT to 60 RT to 60 |
5mM Tartaric acid + 1mM Dipicolinic acid + 1.5g/L Boric acid aq. 5mM Tartaric acid + 1mM Dipicolinic acid + 1.5g/L Boric acid aq. |
| Y-521 Y-G |
5 - |
3.0 - |
RT to 70 RT to 70 |
4mM HNO3 aq. 4mM HNO3 aq. |
| Product name | Plate number (TPN/column) |
Functional group |
Particle size (micron) |
Size(mm) ID x Length |
Shipping solvent |
|---|---|---|---|---|---|
| IC T-521 IC T-G |
> 3,000 Guard column |
Sulfo Sulfo |
12 12 |
4.6 x 150 4.6 x 10 |
4mM HNO3 aq. 4mM HNO3 aq. |
| Product name | Plate number (TPN/column) |
Functional group |
Particle size (micron) |
Size(mm) ID x Length |
Shipping solvent |
Max. usable flow rate(mL/min) |
|---|---|---|---|---|---|---|
| IC R-621 IC R-G |
> 1,000 Guard column |
Sulfo Sulfo |
5 5 |
6.0 x 50 4.6 x 10 |
H2O H2O |
1.5 - |
| Product name | Application | Size(mm) ID x Length |
Contents |
|---|---|---|---|
| IC FL-1 | For general purposes (not for the substitution Y-521L) | - |
One holder and one filter |
| IC FL-1 filter | Replace filter for FL-1 | - |
5 Filters |
| IC FL-2 | Non-metal type (not for the substitution Y-521L) | - |
One holder and one filter |
| IC FL-2 filter | Replace filter for FL-2 | - |
4 Filters |
| IC Y-521L | For the analysis of monovalent cations (used with Y-521) | 8.0 x 50 | - |
| NI-424 I-524A |
· Anion analysis with non-suppressor method · NI-424 supports the simultaneous analysis of fluoride and phosphate ions |
| SI-90 4E SI-50 4E |
· amino analysis with suppressor method · Suitable for the determinaition of fluoride ion. · SI-50 separates the target substance from an organic asid well · Not affected by carbonate system peaks |
| VH-anion 4D | · Anion analysis in wine suppressor method |
| SI-52 4E SI-91 4C |
· For analysis of oxhalidess · SI-52 supports simultaneous analysis of hagogen oxides and general inoganic ions · SI-91 is used with post-column method |
| Product name | Plate number (TPN/column) |
Functional group | Particle size (micron) |
Size(mm) ID x Length |
|---|---|---|---|---|
| IC NI-424 IC NI-G |
> 5,000 Guard column |
Quaternary ammonium Quaternary ammonium |
5 5 |
4.6 x 100 4.6 x 10 |
| IC I-524A IC IA-G |
> 2,000 Guard column |
Quaternary ammonium Quaternary ammonium |
12 12 |
4.6 x 100 4.6 x 10 |
| Produc name | Max. usable pressure(MPa) |
Max. usable flow rate(mL/min) |
Usable temp. range(deg-C) |
Shipping solvent |
|---|---|---|---|---|
| NI-424 NI-G |
6 - |
1.2 - |
20 to 60 20 to 60 |
8mM 4-Hydroxybenzoic acid + 2.8mM Bis-Tris + 2mM Phenylboronic acid + 0.005mM CyDTA aq. |
| I-524A IA-G |
2.5 - |
2.0 - |
RT to 50 RT to 50 |
2.5mM Phthalic acid aq. 2.5mM Phthalic acid aq. |
| Product name | Plate number (TPN/column) |
Functional group | Particle size (micron) |
Size(mm) ID x Length |
|---|---|---|---|---|
| IC SI-90 4E IC SI-90G |
> 5,000
Guard column |
Quaternary ammonium Quaternary ammonium |
9 9 |
4.0 x 250 4.6 x 10 |
| IC SI-50 4E IC SI-90G |
> 10,000
Guard column |
Quaternary ammonium Quaternary ammonium |
5 9 |
4.0 x 250 4.6 x 10 |
| WINE VH-anion 4D WINE VH-anionG 4A |
> 7,000
Guard column |
Quaternary ammonium Quaternary ammonium |
5 9 |
4.0 x 250 4.6 x 10 |
| Product name | Max. usable pressure(MPa) |
Max. usable flow rate(mL/min) |
Usable temp. range(deg-C) |
Shipping solvent |
|---|---|---|---|---|
| SI-90 4E SI-90G |
10 - |
2.0 - |
20 to 60 20 to 60 |
1.8mM Na2CO3 + 1.7mM NaHCO3 aq. 1.8mM Na2CO3 + 1.7mM NaHCO3 aq. |
| SI-50 4E SI-90G |
15 - |
0.8 - |
20 to 60 20 to 60 |
3.2mM Na2CO3 + 1.0mM NaHCO3 aq. 3.2mM Na2CO3 + 1.0mM NaHCO3 aq. |
| VH-anion 4D VH-anionG 4A |
12 - |
1.2 - |
20 to 50 20 to 50 |
3.2mM Na2CO3 + 1.0mM NuaHCO3 aq. 1.8mM Na2CO3 + 1.7mM NaHCO3 aq. |
| Product name | Plate number (TPN/column) |
Functional group | Particle size (micron) |
Size(mm) ID x Length |
|---|---|---|---|---|
| IC SI-52 4E IC SI-52G |
> 14,000 Guard column |
Quaternary ammonium Quaternary ammonium |
5 5 |
4.0 x 250 4.6 x 10 |
| IC SI-91 4C IC SI-90G |
> 2,500 Guard column |
Quaternary ammonium Quaternary ammonium |
9 9 |
4.0 x 100 4.6 x 10 |
| Product name | Max. usable pressure(MPa) |
Max. usable flow rate(mL/min) |
Usable temp. range(deg-C) |
Shipping solvent |
|---|---|---|---|---|
| SI-52 4E SI-52G |
15
- |
1.0
- |
20 to 60 20 to 60 |
3.6mM Na2CO3 aq. 3.6mM Na2CO3 aq. |
| SI-91 4C SI-90G |
5
- |
2.0
- |
20 to 60 20 to 60 |
1.8mM Na2CO3 + 1.7mM NaHCO3 aq. 1.8mM Na2CO3 + 1.7mM NaHCO3 aq. |
| Product name | Application | Size(mm) ID x Length |
Contents |
|---|---|---|---|
| IC FL-1 | For general purposes (not for the substitution Y-521L) | - |
One holder and one filter |
| IC FL-1 filter | Replace filter for FL-1 | - |
5 Filters |
| IC FL-2 | Non-metal type (not for the substitution Y-521L) | - |
One holder and one filter |
| IC FL-2 filter | Replace filter for FL-2 | - |
4 Filters |