Multimode Columns

Print
GS-HQ · SEC is the main separation mode
· With the choice of eluent, the column provides multimode features of reversed phase, HILIC, and ion exchange modes to SEC
· Suitable for the separation of peptides or nucleic acids with similar molecular weights
· Suitable for desalting samples or substituting buffer in protein analysis
 
(Standard columns)
Product codeProduct namePlate number
(TPN/column)
Particle size
(μm)
Size (mm)
I.D. x Length
Shipping
solvent
F7600005
F7600006
F7600007
F7600008
F6710019
Asahipak GS-220 HQ
Asahipak GS-320 HQ
Asahipak GS-520 HQ
Asahipak GS-620 HQ
Asahipak GS-2G 7B
≥ 19,000
  ≥ 19,000
  ≥ 18,000
  ≥ 18,000
(guard column)
6
6
7
7
9
7.5 x 300
7.5 x 300
7.5 x 300
7.5 x 300
7.5 x 50
CH3OH/H2O=30/70
CH3OH/H2O=30/70
CH3OH/H2O=30/70
CH3OH/H2O=30/70
CH3OH/H2O=30/70
Product nameMax. usable
pressure (MPa)
Recommended
flow rate
(mL/min)
Max. usable
flow rate
(mL/min)
Usable temp.
range (°C)
Usable
pH range
GS-220 HQ
GS-320 HQ
GS-520 HQ
GS-620 HQ
GS-2G 7B
6.0
5.0
3.0
3.5
-
0.4 to 0.6
0.4 to 0.6
0.4 to 0.6
0.4 to 0.6
-
1.0
1.0
1.0
1.0
-
4 to 60
4 to 60
4 to 60
4 to 60
4 to 60
2 to 9
2 to 12
2 to 12
2 to 12
2 to 12
Max. usable organic solvent concentration:
100% Methanol, 50% Acetonitrile (GS-320 HQ, GS-520 HQ and GS-620 HQ)
30% Methanol, 50% Acetonitrile (GS-220 HQ)

(Semi-micro columns) *The following semi-micro columns are made to order.
Product codeProduct nameParticle size
(μm)
Size (mm)
I.D. x Length
Standard column
F7750312
F7750311
GS320A-4D
GS320A-4E
6
6
4.6 x 150
4.6 x 250
GS-320 HQ
GS-320 HQ
(Preparative columns) *Preparative columns are made to order.  
Product codeProduct namePlate number
(TPN/column)
Particle size
(μm)
Size (mm)
I.D. x Length
F6810017
F6810018
F6810019
F6810020
F6810034
F6810035
F6810036
F6810037
F6710021
Asahipak GS-220 20F
Asahipak GS-320 20F
Asahipak GS-520 20F
Asahipak GS-620 20F
Asahipak GS-220 20G
Asahipak GS-320 20G
Asahipak GS-520 20G
Asahipak GS-620 20G
Asahipak GS-20G 7B
≥ 8,000
  ≥ 8,000
  ≥ 8,000
  ≥ 8,000
  ≥ 14,000
  ≥ 14,000
  ≥ 14,000
≥ 14,000
(guard column)
13
13
13
13
13
13
13
13
20
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 300
20.0 x 500
20.0 x 500
20.0 x 500
20.0 x 500
7.5 x 50
Product nameFlow rate (mL/min)Standard column
UsualMax.
GS-220 20F
GS-320 20F
GS-520 20F
GS-620 20F
GS-220 20G
GS-320 20G
GS-520 20G
GS-620 20G
GS-20G 7B
4 to 6
5 to 8
4 to 6
4 to 6
4 to 6
5 to 8
4 to 6
4 to 6
-
8
12
8
8
8
12
8
8
-
GS-220 HQ
GS-320 HQ
GS-520 HQ
GS-620 HQ
GS-220 HQ
GS-320 HQ
GS-520 HQ
GS-620 HQ
(guard column)
[Target molecular weight range and exclusion limit]
Please use the following table for reference purposes only when selecting columns.

Measured with pullulan (eluent: ultrapure water)
Product nameTarget molecular weight rangeExclusion limit
GS-220
GS-320
GS-520
GS-620
300 - 3,000
300 - 20,000
5,000 - 200,000
10,000 - 800,000

7,000
40,000
300,000
1,000,000

Contact us