Polymer-based Columns for Reversed Phase Chromatography (ODP2 HP)

Scroll
ODP2 HP
  • Provides a large theoretical plate number nearly twice as much as generally available polymer-based reversed phase columns do
  • Offers enhanced retention of high polar substances compared to ODS columns
  • Suitable for the analysis of small molecules such as pharmaceuticals in the presence of protein matrix
  • Ideal for LC/MS analysis of high polar compounds
  • Fulfills USP-NF L39 requirements
(Standard columns)   [Housing material: SUS]Scroll
Product code Product name Plate number
(TPN/column)
Functional group Particle size (μm) Column size (mm)
I.D. x Length
F7622001 ODP2 HP-4B   ≥ 3,500 - 5 4.6 x   50
F7622002 ODP2 HP-4D ≥ 10,000 - 5 4.6 x 150
F7622003 ODP2 HP-4E ≥ 17,000 - 5 4.6 x 250
F6714010 ODP2 HPG-4A (guard column) - 5 4.6 x   10
Scroll
Producr name Maximum pressure
(MPa/Column)
Flow rate (mL/min) Temperature
range (℃)
pH range Shipping solvent
Recommended Maximum
ODP2 HP-4B 15 0.3 - 1.0 1.5 20 - 60 3 - 12 H2O/CH3CN=55/45
ODP2 HP-4D 15 0.3 - 1.0 1.5 20 - 60 3 - 12 H2O/CH3CN=55/45
ODP2 HP-4E 15 0.3 - 1.0 1.5 20 - 60 3 - 12 H2O/CH3CN=55/45
ODP2 HPG-4A - - - 20 - 60 3 - 12 H2O/CH3CN=55/45
(Semi-micro columns)   [Housing material: SUS]Scroll
Product code Product name Plate number
(TPN/column)
Functional group Particle size (μm) Column size (mm)
I.D. x Length
F7622004 ODP2 HP-2B ≥ 3,000 - 5 2.0 x   50
F7622005 ODP2 HP-2D ≥ 7.000 - 5 2.0 x 150
F6714011 ODP2 HPG-2A (guard column) - 5 2.0 x   10
Scroll
Producr name Maximum pressure
(MPa/Column)
Flow rate (mL/min) Temperature
range (℃)
pH range Shipping solvent
Recommended Maximum
ODP2 HP-2B 12 0.1 - 0.2 0.4 20 - 60 3 - 12
H2O/CH3CN=55/45
ODP2 HP-2D 15 0.1 - 0.2 0.4 20 - 60 3 - 12 H2O/CH3CN=55/45
ODP2 HPG-2A - - - 20 - 60 3 - 12
H2O/CH3CN=55/45
(Preparative columns)   [Housing material: SUS]  *Preparative columns are made to order.Scroll
Product code Product name Plate number
(TPN/column)
Particle size
(μm)
Column size (mm)
I.D. x Length
Shipping solvent Standard
column
F6822001 ODP2 HP-10E ≥ 9,500 6 10.0 x 250 H2O/CH3CN=55/45 ODP2 HP
F6714015 ODP2 HPG-7B (guard column) 6   7.5 x   50 H2O/CH3CN=55/45 (guard column)

Operation Manual / Certificate of Analysis

Operation Manuals and Certificate of Analysis / Inspection Certificate for the following products can be downloaded here.

Product Name Index

Related Products

Product Information (Related Information)

General Information on Packed Columns

introduction of column cleaning procedure and column test conditions etc.